Fisher & Paykel AirSpiral Tubing

Sold as Each

AirSpiral Tube offers a heating spiral tubing, warms the air that passes through the tube and resolve the peculiar sounds and cold drips that are common with other heated tubes. AirSpiral also produces 93% less condensation that helps the delivery system in giving patient optimal care. This product is also for use at flows from 2 to 60 L/min depending on the patient interface. Compatible patient interfaces: nasal cannula, tracheostomy direct connection, mask adapter.

Features:

  • Connects with both Optiflow & Optiflow Junior interfaces
  • No external probes, cables, or adaptors required
  • Comes with molded clips to attach tubing to clothes or bedding to assist with tube placement
  • 6 feet long
  • Integrated temperature sensor

Suggested Use:

  • Connect breathing tube to MyAIRVO 2
  • Make sure blue connector is fully located into place
  • Connect breathing tube to patient interface once the system has warmed up
  • Position breathing tube below patient interface so that condensate flows away from the patient
  • Connect breathing tube clip to patient clothing or bedding
    • Note: connecting to patient clothing may not be suitable for all patient groups
  • This product is intended to be used for a maximum of 60 days for home and long-term care facility use, provided that the myAirvo cleaning and maintenance instructions are followed
  • Do not soak, wash or sterilize
  • To avoid burns:
    • Do not allow the breathing tube to remain in direct contact with skin for prolonged periods of time
    • Do not use in the presence of a naked flame, to avoid fires
    • Do not add heat to any part of the breathing tube e.g. covering with a blanket
  • To prevent condensation:
    • Use in a room warmer than 18°C (64°F)
    • Remove/minimize the impact of anything that may cool the heated breathing tube, e.g. a fan, air conditioning, open window
  • To manage excessive condensation:
    • Place the myAirvo below patient head height
    • Drain condensate back into the water chamber
    • At higher target flow settings it may be necessary to first reduce the target flow setting to 30 L/min, to ensure that the condensate drains safely and effectively
    • Disconnect the patient interface from the heated breathing tube
    • Lift the patient end of the heated breathing tube, allowing the condensate to run into the water chamber

Warning:

  • For single patient use only
  • Reuse may result in transmission of infectious substances
  • Attempting to reprocess will result in degradation of materials and render the product defective
  • Using the breathing tube for longer than the specified time can result in serious injury including infection
  • Never operate the unit if the breathing tube has been damaged with holes, tears or kinks
  • Do not block the flow of air through the unit and breathing tube
  • Avoid contact with chemicals, cleaning agents, or hand sanitizers
  • Use only USP sterile/distilled water for inhalation, or equivalent when using the Auto-fill Chamber
  • Use of a non-approved accessory could impair performance or compromise safety
SKU FPMYAIRSPIRAL
Barcode # MYAIRSPIRAL
Brand Fisher & Paykel
Unit Of Measure Each