Fisher & Paykel
MyAIRVO 2 Airspiral Tubing
Each
UPC: MYAIRSPIRAL
SKU Code: FPMYAIRSPIRAL
Fisher & Paykel AirSpiral Tubing
Sold as Each
AirSpiral Tube offers a heating spiral tubing, warms the air that passes through the tube and resolve the peculiar sounds and cold drips that are common with other heated tubes. AirSpiral also produces 93% less condensation that helps the delivery system in giving patient optimal care. This product is also for use at flows from 2 to 60 L/min depending on the patient interface. Compatible patient interfaces: nasal cannula, tracheostomy direct connection, mask adapter.
Features:
- Connects with both Optiflow & Optiflow Junior interfaces
- No external probes, cables, or adaptors required
- Comes with molded clips to attach tubing to clothes or bedding to assist with tube placement
- 6 feet long
- Integrated temperature sensor
Suggested Use:
- Connect breathing tube to MyAIRVO 2
- Make sure blue connector is fully located into place
- Connect breathing tube to patient interface once the system has warmed up
- Position breathing tube below patient interface so that condensate flows away from the patient
- Connect breathing tube clip to patient clothing or bedding
- Note: connecting to patient clothing may not be suitable for all patient groups
- This product is intended to be used for a maximum of 60 days for home and long-term care facility use, provided that the myAirvo cleaning and maintenance instructions are followed
- Do not soak, wash or sterilize
- To avoid burns:
- Do not allow the breathing tube to remain in direct contact with skin for prolonged periods of time
- Do not use in the presence of a naked flame, to avoid fires
- Do not add heat to any part of the breathing tube e.g. covering with a blanket
- To prevent condensation:
- Use in a room warmer than 18°C (64°F)
- Remove/minimize the impact of anything that may cool the heated breathing tube, e.g. a fan, air conditioning, open window
- To manage excessive condensation:
- Place the myAirvo below patient head height
- Drain condensate back into the water chamber
- At higher target flow settings it may be necessary to first reduce the target flow setting to 30 L/min, to ensure that the condensate drains safely and effectively
- Disconnect the patient interface from the heated breathing tube
- Lift the patient end of the heated breathing tube, allowing the condensate to run into the water chamber
Warning:
- For single patient use only
- Reuse may result in transmission of infectious substances
- Attempting to reprocess will result in degradation of materials and render the product defective
- Using the breathing tube for longer than the specified time can result in serious injury including infection
- Never operate the unit if the breathing tube has been damaged with holes, tears or kinks
- Do not block the flow of air through the unit and breathing tube
- Avoid contact with chemicals, cleaning agents, or hand sanitizers
- Use only USP sterile/distilled water for inhalation, or equivalent when using the Auto-fill Chamber
- Use of a non-approved accessory could impair performance or compromise safety
SKU | FPMYAIRSPIRAL |
Barcode # | MYAIRSPIRAL |
Brand | Fisher & Paykel |
Unit Of Measure | Each |