Fisher & Paykel MyAIRVO 2 Tracheostomy Direct Interface

Sold as Each

Optiflow Tracheostomy Interface offers a humidified high flow therapy for tracheostomy patients. This patient interface is mainly used to deliver humidified respiratory gases.

Features:

  • Evaqua technology - designed to reduce the formation of condensation
  • 93% less condensate - connects to our AirSpiral™ breathing tube for 93% less condensate
  • Stable Easy to use - re-designed sputum guard provides stability and ease of use
  • Optimally humidified gas is delivered directly into the tracheostomy, minimising discomfort around the tracheostomy site
  • Lightweight and extremely flexible interface tube
  • Lanyard designed to take the weight of the circuit off the tracheostomy tube

Suggested Use:

  • To ensure loading and movement on tracheostomy tube is kept to a minimum, make sure the lanyard is secured properly
  • Lanyard position is not suitable for patients with damaged skin
  • Connect to the humidification system
  • Make sure all connections are secure
  • If using an MR850, attach the tubing clip to the breathing circuit but ensure probe cable is not crushed by tubing clip
  • Orientate the sputum guard so that sputum drains downwards
  • The sputum guard can be removed if required

Warning:

  • Appropriate patient monitoring must be used at all times
  • Failure to monitor the patient may result in loss of therapy, serious injury or death
  • Do not obstruct and or modify any part of the interface to avoid hypoxia from loss of therapy
  • Do not use with an air entrainer, to avoid over-pressure
  • Do not use near a naked flame, to avoid fires
  • Do not crush or stretch tube, to prevent loss of therapy
  • For single patient use only. Reuse may result in transmission of infectious substances
  • Attempting to reprocess will result in degradation of materials and render the product defective
  • The lanyard poses a potential risk of strangulation to vulnerable patients (e.g. children)
  • The lanyard is designed to minimize loading and movement of the tracheostomy tube
  • Secure the lanyard properly to avoid accidental decannulation or airway damage
  • The sputum guard is intended to be detachable which may pose a choking risk

Caution:

  • Failure to use the set-up described above can compromise performance and affect patient safety
  • Before connecting the interface, check for adequate gas flow and ensure that the system has warmed up
  • Check for condensate regularly
  • Drain as required
  • Do not use if packaging is not sealed

Hospital Use:

  • This product is intended to be used for a maximum of 14 days
  • Do not soak, wash or sterilise

Home Use: This product is intended to be used for a maximum of 30 days providing daily and weekly cleaning instructions are followed(Please see myAIRVO 2 User Manual).

SKU FPOPT970
Barcode # OPT970
Brand Fisher & Paykel
Unit Of Measure Each

Related products

More From This Category

Test Lung - For use with the Neopuff Neonatal / infant resuscitator

Fisher & Paykel

Test Lung

Each

$53.95

RD020-01

QTY